Linear Tap-changer

You Professional Linear Tap Changer Suppliers!

 

In the 1980s, Liaoning Jinli Electric Power Electrical Appliance Co., Ltd was founded in Dandong city China and went on the road for hard entrepreneurship with strong beliefs. Our company is specialized in developing and manufacturing all kinds of tap changers. Currently, the product line includes on load capacity and voltage regulating tap-changer、on-load tap changer、drum type tap selector、cage type tap changer、linear tap changer、round type tap selector and other more products which are total over 5000 kinds of specifications and more than 30 patents.

 

 
First 1234567 Last 1/10
 
Why Choose Us?
 
 

Our Factory

Liaoning Jinli covered 10000m2 area locates in Tongxing Industrial Park in Dandong.The company's total investment is 150 million Yuan, the total numbers of employees are more than 200 people, and the annual output value is more than 70 million Yuan.

 
 
 

Production Equipment

At present, we have 3 units of international advanced level machining center equipment, 30 units of CNC lathes, 50 sets of instrument lathes and ordinary lathes, 10 units of wire cutting machines, 10 units of CNC milling machines and 28 units of stamping and injection molding equipment, all of which lead to enlarge market shares and high quality of production.

 
 
 

Quality Control

According to ISO9001:2008 quality management system inspection process, to ensure product quality meets customer's requirements, the company takes strictly to control every production link from raw material purchasing to completed product outbound, establish a complete laboratory and equip with advanced instruments.

 

 

Linear Tap Changer For Transformer

 

Types of Tap Changer

Power transformers utilize two basic types of tap changers:
♦ De-Energized Tap Changers (DETC)
♦ On-Load Tap Changers (OLTC)

 

Product Specification

 

We offer the following Product Specifications:

 

Tap Changer

L

B

C

D

Ød1

Ød2

H

Holes on tank cover(mm)

WSTII2 30/ 10-6X5S2

455

55

55

55

3.1

5

H=70,100,130, 150, 200

(Desided by user)

Ø20.5 +0.5

WSTII2 63/ 10-6x5S2

5.1

7

WSTII2 30 / 20-24-6x5S2

455

55

55

55

3.1

5

WSTII2 63 / 20-24-6x5S2

5.1

7

WSTII230 / 30-35-6x5S2

530

80

80

80

3.1

5

WSTH2 63/30-35-6x5S2

5.1

7

 

 

Application of Linear Tap Changer

Distribution transformers: In distribution systems, tap changers are used to maintain voltage stability and ensure the normal operation of power equipment. When the system voltage is higher or lower than the rated voltage, the output voltage can be reduced or increased by adjusting the position of the tap changer.

 

Special purpose transformers: In equipment such as arc furnaces that require frequent voltage adjustment, the application of on-load tap changer is particularly important. It ensures that the arc furnace can obtain a stable voltage supply at different working stages, thereby improving production efficiency and product quality.

 

Grid regulation: In the power grid, tap changers are also used to adjust voltage to ensure the stability and reliability of the power system. By adjusting the position of the tap changers, the voltage distribution in the power grid can be balanced, reducing voltage fluctuations and losses.

Linear Tap Changer For Transformer

 

ABB Type Tap Changer Ubb

 

Material of Linear Tap Changer

Leaf spring with painted and quenched. Clip made of pure copper with silver plated.Have excellent anti-corrosion, flexibility and strength.
Toothed gear made of PA66 (reinforced nylon).Have excellent strength and durability.
Connector made of pure copper with pickling passivation Have excellent electrical properties, antioxidant and durability. Polymer composite insulated rod made of glass fiber and epoxy resin by high temperature pultrusion.Have excellent strength and insulating properties.
Knob made of aluminum alloy with surface painting treatment Have excellent anti-corrosion.

 

Install Location of Tap Changer

 

 

A tap changer, no matter if DETC or OLTC, can be mounted on the primary or secondary side of the transformer. The choice is purely technical depending on currents and voltages. For power transformers the tap changer is often installed on the star-connected winding (wye) close to the star point. Obvious advantage is the reduced insulation level.

 

In VFD transformers the tap changer is mounted on the primary (grid) side – at least we have never seen anything else. The selection is rather straight-forward, particularly in multi-winding transformers. Mounting the tap changer on converter side windings would require a dedicated tap changer for each secondary winding. Moreover, converter side windings are exposed to much higher harmonic distortion than the grid side windings. Finally, converter side windings are also exposed to a common mode voltage: Another good reason to keep the tap changer on the primary side.

 

 

Packaging & Delivery

 

 

20230829095954fca668d597974b9ca967c7bda120c256.jpg (750×695)

 

 

Certificate

 

 

201712151318485161155.BMP (360×241)201712151318584180469.jpg (360×241)

201712151318195981275.jpg (360×479)201712151318306817392.jpg (360×479)

 

 

FAQ

 

 

Q: What is the working principle of tap changer?

A: The purpose of a tap changer is to regulate the output voltage of a transformer. It does this by altering the number of turns in one winding and thereby changing the turns ratio of the transformer. There are two types of transformer tap changers: an on-load tap changer (OLTC) and a deenergised tap changer (DETC).

Q: What is the IEC standard for on-load tap changer?

A: IEC 60214-1:2014 applies to on-load tap-changers of both resistor and reactor types, de-energized tap-changers, and their motor-drive mechanisms.

Q: What is the voltage regulation for tap change?

A: Voltage Regulation through Tap Changes: The primary purpose of the OLTC is to maintain a stable output voltage. If there is a drop in voltage due to increased demand, the OLTC shifts to a tap with a higher voltage by adding more turns to the winding, compensating for the drop.

Q: What is the voltage of tap changer?

A: On-load tap changer
On-load tap changers (OLTC) are mostly with oil-immersed transformer connected to the utility power supply at a voltage level exceeding 34.5kV.

Q: Are you a factory or a trading company ?

A: We are a factory and trading company at the same time.

Q: How about the quality of the products ?

A: Our products are of high quality and we have registered and reputable brands.

Q: What's the MOQ for each items ?

A: 1 pieces.

Q: What's our shipping ways ?

A: We can provide different types of shipping such as sea, air, and land.

Q: What is your terms of packing?

A: Generally, we pack our goods in neutral white boxes and cartons. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.

Q: What is your terms of payment?

A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q: How about your delivery time?

A: Generally, it will take 20 to 30 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.

We're professional manufacturers and suppliers specialized in transformer part linear tap-changer. We provide top quality electrical device and power equipment linear tap-changer transformer accessory for customers. Also, customized service is supported.

tap changer for automotive industry, tap changer for power warranty governance, tap changer for power stability governance

(0/10)