Series-parallel 3 combined tap-changer As the name indicates, in this method tap changing is done after disconnecting the load from the transformer. Off load tap changing is normally provided in low power, low voltage transformers. It is the cheapest method of tap changing. The tap changing is...
Series-parallel 3 combined tap-changer
As the name indicates, in this method tap changing is done after disconnecting the load from the transformer. Off load tap changing is normally provided in low power, low voltage transformers. It is the cheapest method of tap changing. The tap changing is done manually though hand wheel provided in the cover. In some transformers arrangements to change the taps by simply operating the mechanical switches are also provided.
We feel proud to introduce ourselves as one of the well-known manufacturers and exporters of Series-parallel connection combined Tap Changer. The offered tap changer is widely used for the testing of transformer. Our manufactured tap changer is provided with motor drives for achieving quick voltage change. The exported coarse type tap changer is capable of generating a variable voltage range, for testing purposes. Our manufactured coarse type tap changer is available at very affordable market rates.
Model Explanation
WST □ - □/□-□╳□
W: off-circuit
S : three-phase or D for single phase
T : linear type tap chager
□: voltage regulation model
□: rated current
□: rated voltage
□: number of tapping heads
□: number of tapping position
Voltage Regulation Model
I : terminal point
II : central point
III : neutral point
IV : Y-△ conversion
V : series-parallel connection
Samples Technical Data
Specifications | WST 30 | WST 63 | WST 125 | WST 250 | WST 400 | WST 500 | |
Phase number | three-phases | ||||||
Connection mode | Central point(Ⅱ) Neutral Point(Ⅲ) Terminal Point(Ⅰ) | ||||||
Rated through current(A) | 30 | 63 | 125 | 250 | 400 | 500 | |
Short-circuit capacity | Heat stableness current(KA/2s) | 0.7 | 1.6 | 2.5 | 3.75 | 4 | 5 |
Dynamic stableness current(KA) | 1.8 | 4 | 6.25 | 9.375 | 10 | 12.5 | |
Rated frequency | 50~60 | ||||||
Insulation level(KV) | Rated Voltage | 10KV | 20KV | 35KV | |||
Power-frequency withstand Voltage(50Hz/1min) | 42KV | 55KV | 95KV | ||||
Impulse(1.2/50μs) | 75KV | 125KV | 250KV | ||||
Sealing Performance(KPa/24h) | 60 | ||||||
Machine life(Thousands of times) | 2 |