On-load Tap Changer

You Professional On Load Tap Changer Suppliers!

 

In the 1980s, Liaoning Jinli Electric Power Electrical Appliance Co., Ltd was founded in Dandong city China and went on the road for hard entrepreneurship with strong beliefs. Our company is specialized in developing and manufacturing all kinds of tap changers. Currently, the product line includes on load capacity and voltage regulating tap-changer、on-load tap changer、drum type tap selector、cage type tap changer、linear tap changer、round type tap selector and other more products which are total over 5000 kinds of specifications and more than 30 patents.

 

 
First 123456 Last 1/6
 
Why Choose Us?
 
 

Our Factory

Liaoning Jinli covered 10000m2 area locates in Tongxing Industrial Park in Dandong.The company's total investment is 150 million Yuan, the total numbers of employees are more than 200 people, and the annual output value is more than 70 million Yuan.

 
 
 

Production Equipment

At present, we have 3 units of international advanced level machining center equipment, 30 units of CNC lathes, 50 sets of instrument lathes and ordinary lathes, 10 units of wire cutting machines, 10 units of CNC milling machines and 28 units of stamping and injection molding equipment, all of which lead to enlarge market shares and high quality of production.

 
 
 

Quality Control

According to ISO9001:2008 quality management system inspection process, to ensure product quality meets customer's requirements, the company takes strictly to control every production link from raw material purchasing to completed product outbound, establish a complete laboratory and equip with advanced instruments.

 

 

Line Tap-changer

 

Overview of On Load Tap Changer

An OLTC is an essential part of distribution networks which is typically constructed as an autotransformer. Automatically adjustable OLTCs are commonly used at distribution substation to raise the starting voltage for a feeder under a load so as to keep the desired voltage along the feeder while compensating the feeder voltage drop . The secondary side voltage magnitude across the load changes depending upon the operation of tap changers.

 

 

Advantages of On Load Tap Changer

Stable voltage. As the power load of the power grid is constantly changing, the line loss and voltage drop are also changing. If the compliance changes greatly, the voltage drop of the power grid cannot be stable. After using the on load tap changer, the voltage of regional power grid or key users can be stabilized within the allowable voltage deviation range.

 

Save electricity. The on load tap changer can stabilize the system voltage, increase the power factor, reduce the line loss and reduce the investment of reactive power compensation equipment.

 

Connect to the power grid. The interconnection of several power grids is of great significance to power supply reliability, economic operation and flexible dispatching. The on load tap changer is used to connect the power grid. The grid voltage can be increased when the power consumption peak is high, and the grid voltage can be reduced when the power consumption is low, so as to ensure the voltage quality.

On load Tap Changer Reactive device

 

Product Specification

 

We offer the following Product Specifications:

 

Sr.No.

Parameters

Value

1

Voltage ratings:

11 KV to 33 kV

2

Tap position

17 Nos

3

Step voltage

Max 300 volt for 11 KV
412 volts for 33 KV.

4

Motor voltage

415 volt

5

Control voltage

110 volt

 

Application of On Load Tap Changer
 

High Voltage Power Transformers

OLTCs are widely used in high voltage power transformers where continuous voltage regulation is essential without interrupting the load.

Power Generation Stations

They are employed in power generation plants to stabilize and regulate voltage before power is transmitted through the grid.

Substations (Above 110 kVA)

OLTCs are commonly used in substations rated above 110 kVA, where voltage adjustments are frequently required to meet varying load demands.

Industrial Power Systems

In large industrial facilities, OLTC-equipped transformers help maintain stable voltage levels, ensuring smooth operation of sensitive machinery.

 

On Load Tap Changer power distribution

 

Structure and Operation of On Load Tap Changer

An OLTC has three principal parts: The selector switch, the motor drive, and tap connections on the high side of the power transformer. The selector switch will determine a tap position as suitable for the prevailing conditions, and the motor drive moves the tap changer to this selected position.

 

The motor drive turns the tap changer up or down just before the OLTC switches to a new tap. This results in normal movement of contacts from one tap to another, which yields a new electrical connection.

 

The OLTC basically keeps your transformer running efficiently by cutting-in or switching voltage levels with no interruption to keep power flow steady!

 

 

Packaging & Delivery

 

 

20230829095954fca668d597974b9ca967c7bda120c256.jpg (750×695)

 

 

Certificate

 

 

201712151318485161155.BMP (360×241)201712151318584180469.jpg (360×241)

201712151318195981275.jpg (360×479)201712151318306817392.jpg (360×479)

 

 

FAQ

 

 

Q: What is on load and offload tap changer?

A: In the No-load tap-changing transformer (NLTC), the main supply connection is disconnected while changing the tap. Whereas on-load tap changing transformer (OLTC) there will be continuous power supply even when tap positions change.

Q: What is the tapping of the transformer?

A: Whenever a voltage is supplied to a transformer it should be controlled properly, hence in order to maintain the stability of the voltage supply based on the capacity of the transformer we use the tapping concept.

Q: On which side the tap changer is usually located and why?

A: Tap changers can be connected at various points in a transformer to either primary or secondary windings. It becomes easy to access HV windings when a tap is placed on the HV side because HV is wounded with LV and also it reduces lightening risk when breaking down.

Q: How do taps work on a transformer?

A: Taps control secondary voltage in a transformer.

Q: Are you a factory or a trading company ?

A: We are a factory and trading company at the same time.

Q: How about the quality of the products ?

A: Our products are of high quality and we have registered and reputable brands.

Q: What's the MOQ for each items ?

A: 1 pieces.

Q: What's our shipping ways ?

A: We can provide different types of shipping such as sea, air, and land.

Q: What is your terms of packing?

A: Generally, we pack our goods in neutral white boxes and cartons. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.

Q: What is your terms of payment?

A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q: How about your delivery time?

A: Generally, it will take 20 to 30 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.

We're professional manufacturers and suppliers specialized in transformer part on-load tap changer. We provide top quality electrical device and power equipment on-load tap changer transformer accessory for customers. Also, customized service is supported.

atlantic ocean market of on-load tap changer, indian ocean market of on-load tap changer

(0/10)

clearall