Our Factory
Liaoning Jinli covered 10000m2 area locates in Tongxing Industrial Park in Dandong.The company's total investment is 150 million Yuan, the total numbers of employees are more than 200 people, and the annual output value is more than 70 million Yuan.
Production Equipment
At present, we have 3 units of international advanced level machining center equipment, 30 units of CNC lathes, 50 sets of instrument lathes and ordinary lathes, 10 units of wire cutting machines, 10 units of CNC milling machines and 28 units of stamping and injection molding equipment, all of which lead to enlarge market shares and high quality of production.
Quality Control
According to ISO9001:2008 quality management system inspection process, to ensure product quality meets customer's requirements, the company takes strictly to control every production link from raw material purchasing to completed product outbound, establish a complete laboratory and equip with advanced instruments.

Plate Tap Changer improved product which adopts new structure,new materials,new technology,having the advantages of reasonable structure,good hand-feeling,flexible rotary,reach the position accurately etc.Central point customized round off load tap changers are used to change the transmission ratio in order to adjust the transformer to grid conditions. Therefore the tap changers have several pins to connect with the coil windings.
We offer the following Product Specifications:
|
Model No. |
Rated current
|
Rated voltage |
Voltage regulating
|
ΦD, Φd |
Power frequency withstand voltage (kv/1 min) |
||
|
To earth |
Inter phase |
Inter contact |
|||||
|
WSB Ⅱ 30-63/10-20 8*7 |
30A – 63A |
10KV |
Central point |
D=6, 7mm d=4.3, 5.1mm |
42 |
42 |
18 |
|
20KV |
55 |
55 |
20 |
||||
Standard Tap: This is the point where we obtain rated secondary voltage when rated primary voltage is applied.
Negative Portion: In this portion, the number of turns is less with respect to the standard tap. Means as the tap changer moved to negative portion the number of turns from which output is taken will decrease but output is not necessary to decrease.
Positive Portion: In this portion, the number of turns is more with respect to the standard tap.Means as the tap changer moved to positive portion the number of turns from which output is taken will increase but output is not necessary to increase.


When the supply voltage can not meet the normal voltage requirements,it can be adjusted by changing the tap changer of transformer.When changing the tap changer, the transformer must be disconnected from the power grid and carried out without load.Open the protective cover of the tap changer and screw down the screw connecting the pointer and the locating plate,and use a wrench to pull the operating shaft to the required gear.
If necessary, DC resistance of each phase should be measured (which can reflect the contact condition of tap changer).
As the contact of tap changer may be burned or oxide layer is formed, it is easy to cause poor contact. So it is necessary to measure the DC resistance.Large transformer can be measured by two-arm bridge,The capacity of rural transformer is not big, so it can be measured by single-arm bridge.The cross-sectional area of the measured connecting wire should be larger, and the wire connection must be good.
The measurement results should be compared with the value on the name plate, and there should be no obvious change.




We're professional manufacturers and suppliers specialized in transformer part plate tap changer. We provide top quality electrical device and power equipment plate tap changer transformer accessory for customers. Also, customized service is supported.
business opportunity team of tap changer plate, pay per click advertising of tap changer plate, social media marketing of tap changer plate