Series-parallel Off Load Tap Changer

S eries- P arallel Off Load Tap Changer A tap changer is a device fitted to power transformers for regulation of the output voltage to required levels. This is normally achieved by changing the ratios of the transformers on the system by altering the number of turns in one winding of the...

  • Product Introduction

Series-Parallel Off Load Tap Changer

A tap changer is a device fitted to power transformers for regulation of the output voltage to required levels. This is normally achieved by changing the ratios of the transformers on the system by altering the number of turns in one winding of the appropriate transformer/s. Supply authorities are under obligation to their customers to maintain the supply voltage between certain limits. Tap changers offer variable control to keep the supply voltage within these limits.

Tap-changer can either be resistive or reactive. The tap changer with a resistive type of impedance uses high speed switching, whereas the reactive type uses slow moving switching. High speed resistor switching is now the most popular method used worldwide, and hence it is the method that is reviewed in this report.
The tapped portion of the winding may be located at one of the following locations, depending upon the type of winding:
(a) At the line end of the winding;
(b) In the middle of the winding;
(c) At the star point.

Model Explanation
 WSL□ □/□-□╳□ □
    W:  off-circuit
    S :  three-phase
    L :  cage type
    □:  voltage regulation model  
    □:  rated current
    □:  rated voltage
    □:  number of tapping heads
    □:  number of tapping position
    □:  L for vertical ; W for horizontal
    D for top tank installation; WD for bell-type installation  

Voltage Regulation Model
    I  :  linear regulating
    II :   central point
    III :  neutral point
   IV :  Y-△ conversion
    V :   series-parallel connection
   VI:   positive and negative regulation 

Samples Technical Data

Model No.

Voltage regulating

Installation dimension( mm )

Power frequency

withstand voltage

(KV/1min)

L1

L2

L

Md

To earth

Inter phase

Inter contact

WSLⅡ 200~630/10-6×5~10×9  D

Central point

150

110

480

200A:Md=M12;400A:Md=M16;630A:Md=M18

45

45

18

WSLⅢ 200~400/10-5×5~10×10  D

Neutral point

150

110

480

WSLⅡ 200~630/35-6×5~10×9  D

Central point

210

170

650

95

95

30

WSLⅢ 200~400/35-5×5~10×10  D

Neutral point

210

170

650

WSLⅡ 200~630/66-6×5~8×7  D

Central point

380

240

953

140

140

45

WSLⅢ 200~400/66-5×5~8×8  D

Neutral point

380

240

953

140

95

30

WSLⅡ 200~630/110-6×5 D

Central point

470

400

1370

230

230

55

WSLⅢ 200~400/110-6×6  D

Neutral point

470

400

1370

230

140

45

Hot Tags: series-parallel off load tap changer, China, manufacturers, suppliers, transformer, customized, transformer part, transformer accessory, electrical device, power equipment, power plant requirements tap changer, tap changer motor, tap changer for power transformer, tap changer switch, order tap changer, tap changer efficiency improvement