Bridge Regulation on Load Tap Changer
Bridge Regulation On Load Tap Change Factory are used to change either the primary or secondary voltage to more closely match the desired input or output voltage. This is usually done when operating conditions have changed and the voltage is different than what is normally desired or required to...
- Product Introduction
Bridge Regulation On Load Tap Change
Factory are used to change either the primary or secondary voltage to more closely match the desired input or output voltage. This is usually done when operating conditions have changed and the voltage is different than what is normally desired or required to re-establish “normal” operating conditions. When this occurs, changing one or more of these taps can more exactly provide the desired voltage. Because it is a change that requires actually moving cables, lugs and conductors, this sort of manual voltage regulation is usually done when all other options have been exhausted and is not usually intended for frequent changes.
Tap changing can control / change the voltage (8 to 10%) at the receiving end by manipulating the reactive power flow. It can also control / change slightly the phase angle (phase shifting) thereby affecting the real power flow. Tap changing can be off-load or on-load. In modern power system practice tap changing is rarely used as it has been found, more often than not, to adversely affect the power system Voltage Stability.
We pride ourselves on quality which is our best selling point. Our business goal is to build smart electrical appliance to match our customer’s requirements. We can satisfy various requirement of tap changer. We can undertake designing and making all kinds of special switches according to the technical parameters, special structure and quality required by the customers.
Model Explanation
SY□Z(Z) - □/□-□L
S : three-phase
Y : on load
□: voltage connection model
Z : adopting resistance transit
Z : direct switch
□: rated current
□: rated voltage
□: number of voltage regulation grades
L : online oil filter
Main Technical Data
Application Scope |
Oil-immersed Distribution Transformer |
Connection Model |
SYXZZ : three phase Y connection neutral point linear voltage regulation SYJZZ : three phase central point bridge voltage regulation SYTZZ : three phase any connection linear voltage regulation |
Three-phase Max. Rated Current |
400A |
Max. Rated Voltage |
600V |
Max. Voltage of Device Um |
40.5KV |
Tap Positions |
17 or others |
Connection Model Shows as Following
□![]() |
□![]() |
□![]() |
(Y connection neutral point) | (Y connection neutral point with lead wire) | (Y connection central bridge point) |
□![]() |
□![]() |
□![]() |
(D connection central bridge point) | (D connection terminal point) | (Auto type terminal point) |
Sample Outline Dimension Diagram
Sample Model Parameters
Serial number |
Model No. |
(A) Rated current |
(v) Rated voltage |
Installation dimension(mm) |
||||
H |
H1 |
H2 |
H3 |
Md |
||||
1 |
SYXZZ 50/10 -3~5 |
50 |
10 |
615 |
305 |
120 |
60 |
M8 |
2 |
SYXZZ 100/10-5~9 |
100 |
10 |
682 |
350 |
125 |
66 |
M8 |
3 |
SYJZZ 100/10-5~7 |
100 |
10 |
750 |
440 |
125 |
100 |
M8 |
4 |
SYJZZ 200/35-5~9 |
200 |
35 |
1500 |
190 |
170 |
715 |
M12 |
5 |
SYJZZ 300/35-5~9 |
300 |
35 |
1500 |
190 |
170 |
715 |
M14 |
6 |
SYJZZ 400/35-5~9 |
400 |
35 |
1700 |
220 |
235 |
910 |
M16 |
Hot Tags: bridge regulation on load tap changer, China, manufacturers, suppliers, transformer, customized, transformer part, transformer accessory, electrical device, power equipment, tap changer selector, innovation trends tap changer, durability comparison tap changer, tap changer resistor, acquire tap changer, purchase tap changer